TECHNICAL PARAMETERS | |
[Test Items] Formed elements analysis | RBC, WBC, SQEP, NSE, HYAL, UNCC, CRYS, MUCS, BACT, BYST, WBCC and
SPRM. UTI screening, Microscopic Testing screening, RBC source, Cocci
screening | |
[Test Items] Chemistry analysis | UBG, BIL, KET(sensitivity no more than 0.5mmol/l), CRE, BLD,
PRO(sensitivity no more than 0.3g/l), MALB, NIT, LEU(sensitivity no more than ca.15 leuko/ul), GLU, SG, pH, VC, Ca, Color, Turbidity
(Optional items: CRE, MALB, VC, Ca, Color, Turbidity and SG). ACR | VC pad and ACR should be available. |
[Wavelengths] | 525nm, 572nm, 610nm, 660nm | No less than 4 wavelengths |
[Throughput] | Formed elements analysis + Chemistry analysis: 120t/h (maximum); Formed elements analysis: 120t/h (maximum); Chemistry analysis: 240t/h | Sediments tests throughput no less than 110t/h |
[Sample] | Non-centrifuge urine | |
[Sample handling] | Dynamic sample for photographing rather than static one | |
[Sample capacity] | 50 samples (270 samples if equipping pre-storage tray) | No less than 250 samples |
[Sample volume] | Urine formed elements analysis: Minimum 3ml non-centrifugal urine Chemistry analysis: Minimum 2ml non-centrifugal urine (without
refractometer). Minimum 3ml non-centrifugal urine (with refractometer) Urine formed elements analysis+chemistry analysis: minimum 3ml
non-centrifugal urine (Aspirating volume about 1ml) Note: The conical tube is required for above mentioned minimum
quantity. | |
[Aspirated sample volume] | Urine formed elements analysis: about 1.9ml Chemistry analysis: 1.0ml without refractometer 1.2ml with refractometer Urine formed element analysis+chemistry analysis: about 1.8ml | |
[Sheath volume] | Urine formed elements analysis: 15ml±1ml Chemistry analysis: 4.0ml±1ml Urine formed element analysis+chemistry analysis: 15ml±1ml | |
[Max loading strips] | 200 strips | |
[STAT] | Available. | |
[Images] | 650 real images | No less than 600 images |
[Data memory] | No less than 100,000 | |
[Data interface] | RS-232 bi-directional communication interface/network interface.
Bidirectional to LIS/HIS. | |
[Printer] | External printer | |
[Report] | Urine formed elements and chemistry results can be combined into
one report. Images of urine formed elements can be printed on the reports too. | |
[Weight] | 82kg, equipped with optional pre-storage tray 114kg | |
[Dimensions] | 779*688*584mm (W*D*H) Equipped with optional pre-storage tray: 1559mm*897mm*584mm (W*D*H) | Width of the analyzer is no more than 790mm. |
[Power] | ~100-240V, 50Hz, analyzer 250VA, computer 100VA. | |
[Working temperature] | 15℃~35℃ | |
[Relative humidity] | not more than 75% | |